6.1 Permitted characters and character lengths
LOGO! CMR2020 / LOGO! CMR2040
48 Operating Instructions, 09/2014, C79000-G8976-C356-01
Input box
Minimum
character
length
Maximum
character
length
Permitted characters
Non
permitted
characters
Users / groups
Phone numbers
0 20 Digits 0 ... 9 including special characters.
Typical special characters are for example + / *
( ), and spaces. Other special characters are
possible.
Login
1 20 0 ... 9, a ... z, A ... Z, -@_. ßäöüÄÖܧ´€éè
Password
8 20 0 ... 9, a ... z, A ... Z, !“#$%&'()*+,-
./:;<=>?@[\]^_`{|}~
ßäöüÄÖܧ´€éè
Monitoring
SMS message texts includ-
ing up to 3 placeholders for
process values with format-
ting instructions.
The placeholders are re-
placed with real values prior
to sending. The text length
can then exceed the limit of
160 characters. If the maxi-
mum number of characters is
exceeded, up to 2 SMS
messages are generated and
sent.
0 160 0 ... 9, a ... z, A ... Z ... 9,, !.#$%&'()*
+,-./:<=>?@... z
The characters [ and ] are reserved for place-
holders.
The following formats are permitted for the
placeholders of the process values; V stands for
a signal name specified in the signal definitions.
The signal names must not include the charac-
ters [ and ]:
[V] decimal value of the signal
Other placeholders:
[DATE] current date
Format: yyyy-mm-dd
[GPS] value is GPS position
Format: ddd:mm:ss.hs N/S
ddd:mm:ss.hs W/E Alt m
[TIME] current time
Format: hh:mm:ss
[DEVNAME] module name
\^`{|}~
1)
No PIN is also permitted.