Configuration
6.5 Diagnostics
LOGO! CMR2020 / LOGO! CMR2040
64 Operating Instructions, 09/2014, C79000-G8976-C356-01
6.5.3
SMS notifications
Figure 6-6 Diagnostics - "SMS notifications" tab
In the "SMS notifications" tab, you set whether or not a recipient group is notified if an error
occurs (FATAL or ERROR).
Note
Messages without SMS notifications
For messages of the type INFO or WARNING, no SMS notifications are sent.
If the device is put out of operation by a fatal error, no SMS notifications are sent.
1. Select the entry "Yes" from the "Send SMS notifications" drop-down list.
2. Enter the group you defined in "Users / groups" in the "Recipient groups" tab in "Recipient
group".
If no recipient group has been defined yet, the notifications cannot be activated.
The plain text of the error is sent in the SMS message.
If you click the "Apply" button, all the settings you made in the "SMS notifications" tab are
adopted.