Operation
7.2 Monitoring
LOGO! CMR2020 / LOGO! CMR2040
Operating Instructions, 09/2014, C79000-G8976-C356-01
99
Display if the connection between the CMR and BM is interrupted
In the "LOGO! BM" tab, you have configured a connection between the CMR and BM.
You have configured LOGO!-BM signal types in the "Signal definitions" tab.
The connection between the CMR and BM is interrupted, for example by removing the
Ethernet cable:
The error LED of the CMR is lit red.
The "Overview" tab shows all configured signal types of the BM in red characters.
If the "LOGO! BM" signal was configured with the signal types "CS - communications
status", the signal changes to the status "Off".
Note
Delayed display of the interrupted connection
The interrupted connection is detected by the CMR after a delay of several se