Description
1.2 Product characteristics
SIMATIC MV500
14 Operating Instructions, 06/2018, C79000-G8976-C494-01
Communication interfaces
The optical readers have all the conventional communications interfaces of industrial
sensors and can therefore be connected to a wide variety of systems. Through the
communications module interface, they can also be seamlessly combined with the
communications modules (ASM/CM), for example, via PROFIBUS.
Simple operation and commissioning
The optical readers are particularly easy to use and commission, despite the wide variety of
possible applications. For most applications, the parameters are set automatically. If,
however, readjustment becomes necessary, the parameters can be assigned using the
integrated Web server and an Internet browser without prior software installation.
1.2
Product characteristics
The optical reader is a compact camera system with an integrated processing unit for
industrial applications with the following product characteristics:
Reading code
For codes with maximum quality, the read reliability for data matrix code is 99.999 %
(compare quality grading).
Maximum reading speed of 80 reads per second (Rps) in SIMATIC MV500 S
Software-guided read distance variable due to exchangeable lens (typically: 100 mm to
3000 mm)
Object speed up to 10 m/s
Code sizes (example: DMC) from 1 mm
2
to 200 mm
2
Auto-trigger and scan mode
Up to 15 parameter sets and code reading settings can be saved and selected.
Up to 150 codes can be read per image acquisition (SIMATIC MV500 U/X)
Code verification according to ISO/IEC 16022
Integrated communications interfaces
Ethernet 10/100 Mbps for TCP/IP and PROFINET IO
1 trigger input and 1 flash output
Response time of the trigger input: 50-70 us
Jitter (fluctuation of response time): max. 40 ns
Incoming triggers during a running image acquisition do not interrupt it. Triggers that are
incoming during an image acquisition are handled as NOK processing procedures and
included in the processing statistics.
Communication module interface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MV540 H and is the answer not in the manual?

Siemens SIMATIC MV540 H Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MV540 H
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals