Process interfacing via an automation system (PLC, PC)
9.7 Remote client
SIMATIC MV500
162 Operating Instructions, 06/2018, C79000-G8976-C494-01
Note
Keep "XML Backup" file safe
The "XML Backup" file contains sensitive data (password hash). For security reasons, keep
the "XML Backup" file in a safe place.
In order to be able to use these functions, an IP address for the remote client must be stored
in the WBM (Settings > Communication > Interfaces > Archiving/MMI).
The "XML Backup" and "XML Restore" functions each have their own HTTP requests. After
the reader has received one of these HTTP requests, if the requirements have been met, the
following tasks are first performed in both cases:
1. The connection to the WBM is terminated.
While the HTTP request is being processed by the optical reader, you can only open the
WBM in READ ONLY mode.
2. The optical reader changes to "Stop" mode.
3. The IN_OP bit is set to "0".
9.7.2
XML backup
Once the optical reader has sent the HTTP response, the "IN_OP" bit is set and access via
the WBM is permitted again.
Request
Stucture and properties of the request:
URI: http://<IP address of the optical reader>/xml/backup.cgi
e.g. http://192.168.0.42/xml/backup.cgi
HTTP method: GET
Response
Structure and properties of the response:
HTTP status code 200 (OK)
Content type: text/xml
name = "<file name>.xml"
Content disposition: attachment
filename="<file name>.xml"

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MV540 H and is the answer not in the manual?

Siemens SIMATIC MV540 H Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MV540 H
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals