1.6 System components
SIMATIC MV500
20 Operating Instructions, 06/2018, C79000-G8976-C494-01
1.6
System components
Optical reader
To equip an application with optical readers, you need the following hardware components:
SIMATIC MV500 optical reader
Lens suitable for code size and read distance
Ring light
Protective lens barrel
24 V DC, 2 A power supply (tolerance: 19.2 ... 28.8 V):
Alternatively via I/O / CM cable
Alternatively via Power over Ethernet
Communication connection:
RS232/RS422 integrated in the I/O / CM cable
Ethernet cable
PC/PG
Apart from the components for operating the optical reader, you also require a PC/PG to
commission the device:
PC/PG minimum configuration:
Ethernet interface with at least 100 Mbps
CPU: DualCore with 3 GHz
RAM: 4 GB
Software:
Microsoft Windows 7 operating system or newer
Web browser with HTML5 support
Tested Web browsers: Microsoft Internet Explorer as of V11, Mozilla Firefox as of V52
and Google Chrome as of V57
The system requirements of SIMATIC MV500 optical readers for communication partners in
the process depend on the selected communication connection. You can find more
information on communication connections in the section "Network and system integration
(Page 53)".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC MV540 H and is the answer not in the manual?

Siemens SIMATIC MV540 H Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC MV540 H
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals