Process interfacing via an automation system (PLC, PC)
9.7 Remote client
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
165
"[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="xmlfile"
Content-Type: text/xml
<xmlFile>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importtcp"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importdp"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importserial"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importsec"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importcodes"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importcustomgui"
<on|off>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importremoteclientip"
<on|off>
[REMOTEXMLUPLOADPARA]
"
Structure and properties of the response:
● HTTP status code 200 (OK)
● Data:
– "2": XML upload and import were only partially successful.
The optical reader restarts. The XML import must be performed again via the WBM to
obtain error analysis.
– "1": XML upload and import was successful.
The optical reader restarts.
– "0": Import error.
The XML import must be performed again via the WBM to obtain error analysis. The
"IN_OP" bit is set and access via the WBM is allowed again.