Description
1.7 Functional description
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
23
The functions, communication protocols and configurations are largely compatible with the
devices of the SIMATIC MV400 series. The device configurations for these devices can be
imported into the readers of the SIMATIC MV500, enabling a seamless transition from
SIMATIC MV400 to MV500.
Note that after importing an MV400 device configuration, the program must be saved again.
Table 1- 1 Differences / possible incompatibilities
DI trigger, DQ strobe,
DI trigger, DQ strobe,
9.6 ... 115 KB
1 ◆ 1.5 ◆ 2 stop bits
9.6 ... 115 KB
1 ◆ 2 stop bits
RS232, CM, TCP/IP, PN, DI
Client and server Client
(CONNECT button)
✓ ✓
(incompatible with MV400)
The MV400 "Resolution, half" function is no longer available on MV500 due to faster image
acquisition times.
Compatibility restrictions
Note that software release V1.0 does not support the following functions of MV400:
• Calibrated verification (Veri-Genius license),
• Vericode
• OCR (Text Genius) and
• Locator function (Pat genius)