Last Synchronization Time
Shows when the last time-of-day synchronization took place.
Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
Not set
The time was not set.
Manual
Manual time setting
SNTP
Automatic time-of-day synchronization with SNTP
NTP
Automatic time-of-day synchronization with NTP
SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
Daylight Saving Time
Shows whether the daylight saving time changeover is active.
active (offset +1 h)
The system time was changed to daylight saving time; in other words, an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The set time continues to be displayed in the "System Time" box.
inactive (offset +0 h)
The current system time is not changed.
Procedure
1. Click the "SIMATIC Time Client" check box to enable the SIMATIC Time Client.
2. Click the "Set Values" button.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 171