Log text OVPN_{connection name}[{config detail}]: Authenticate/Decrypt packet error:
packet HMAC authentication failed
Standard IEC 62443-3-3 Reference: SR 3.1
Description Integrity check failed (OpenVPN).
Example OVPN_c1[25409]: Authenticate/Decrypt packet error: packet HMAC authentica‐
tion
failed
Severity Warning
Facility local0
A.3.1 Syslog messages SR7.4
Restoration of the automation system
Log text {protocol}: Loaded file type Firmware {version} (restart required).
Standard IEC 62443-3-3 Reference: SR7.4
Description Firmware update was successfully uploaded.
Example TFTP: Loaded file type Firmware V02.00.00 (restart required).
Severity Info
Facility local0
Log text {protocol}: User {user name} loaded file type Firmware {version} (restart required).
Standard IEC 62443-3-3 Reference: SR7.4
Description Firmware update was successfully uploaded.
Example WBM: User admin loaded file type Firmware V02.00.00 (restart required).
Severity Info
Facility local0
Log text {protocol}: Failed to load file type Firmware.
Standard IEC 62443-3-3 Reference: SR7.4
Description Error loading the firmware update.
Example WBM: Failed to load file type Firmware.
Severity Warning
Facility local0
Log text {protocol}: Loaded file type Config (restart required).
Standard IEC 62443-3-3 Reference: SR7.4
Description The configuration is applied.
Example TFTP: Loaded file type Config (restart required).
Appendix A
A.3 Syslog messages
SCALANCE S615 Web Based Management
314 Configuration Manual, 11/2019, C79000-G8976-C388-08