You will find further information on this in the device-specific operating instructions.
Configuration
In the factory settings, the SCALANCE S615 can be reached as follows for initial configuration:
Default values set in the factory
Ethernet interface for the configu‐
ration
(internal)
P1 ... P4 (vlan 1)
Ethernet interface for the connec‐
tion to WAN
(external)
P5 (vlan 2)
IP address 192.168.1.1
Subnet mask 255.255.255.0
WBM Access using HTTPS: TCP port 443
CLI Access using SSH, TCP port 22
User name admin
The user name can be changed after the first logon or after a "Re‐
store Factory Defaults and Restart". Afterwards, renaming "admin"
is no longer possible.
Password admin
The password needs to be changed after the first logon or after a
"Restore Factory Defaults and Restart"
You will find more information in "Web Based Management (Page 61)" and in "Starting and
logging in (Page 62)".
1.3.1 Use in a PROFINET environment
Note
Validity of CCA declaration
The CCA declaration applies to PROFINET RT without the use in media redundancy structures.
Configuration information
When using the device in a PROFINET environment, follow the following configuration
instructions:
Set the "Aging Time" to 45 seconds.
Disable Spanning Tree and enable Passive Listening.
Description
1.3 Requirements for operation
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 17