EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE S615

Siemens SIMATIC NET SCALANCE S615
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scheme
Identifies the access method and the resource type.
https: Secure access to a Web page.
Authority
Contains the address of the destination server
Path
Contains the target path to the resource. The target path can correspond to a directory name
or file name.
Query
A query can contain parameter values for an application.
WAN_IP (keyword): Replaces WAN_IP with current external IP address of the device to
the destination server.
Frag.
Addresses local parts of the resource, e.g. the anchor attribute of a Web page.
Status
Shows the status of the last cRSP / SRS access of the entry.
Enabled
When enabled, this entry is used.
4.5.19 Proxy Server
On this WBM page, you configure the proxy server that is used by various components, for
example SINEMA RC.
Description
Proxy Name
Enter a name for the proxy server.
The table has the following columns:
Select
Select the check box in the row to be deleted.
Name
Shows the name of the proxy server.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 201

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE S615

Related product manuals