EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE S615

Siemens SIMATIC NET SCALANCE S615
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A
A.1 Format of the syslog messages
The devices generate Syslog messages (UDP default port 514) according to RFC 5424 that
contain the following boxes.
HEADER
TIMESTAMP according to RFC 3339
Host name
APPNAME, PROCID and MSGID: If no information is known, the "-" character is output.
PRIORITY
PRIORITY contains the coded priority of the Syslog message broken down into a Severity and
Facility box.
Facility
Severity
VERSION
Set to 1.
HOSTNAME_CONTENT:
IPv4 address according to RFC1035: Each byte is represented in decimal, with a dot
separating it from the previous one. XXX.XXX.XXX.XXX
IPv6 address according to RFC4291 Section 2.2
STRUCTURED DATA
timeQuality block
MESSAGE:
ASCII string in English
Note
Additional information about the meaning of the boxes is available in RFC 5424.
SCALANCE S615 Web Based Management