With the reset button
When pressing the button, remember the information in the section "Reset button" in the
operating instructions.
Follow the steps below to reset the device parameters to the factory settings:
1. Turn off the power to the device.
2. Now press the Reset button and reconnect the power to the device while holding down the
button.
3. Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
4. Now release the button and wait until the fault LED (F) goes off again.
5. The device then starts automatically with the factory settings.
Via the configuration
You will find detailed information on resetting the device parameters using the WBM and CLI
in the configuration manuals:
Web Based Management, section "Restart"
Command Line Interface, section "Reset and Defaults"
Upkeep and maintenance
5.3 Restoring the factory settings
SCALANCE S615 Web Based Management
302 Configuration Manual, 11/2019, C79000-G8976-C388-08

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE S615 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE S615 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE S615
CategoryNetwork Router
LanguageEnglish

Related product manuals