In the table, configure the NTP server
Select
Select the row you want to delete.
NTP Server Index
Number corresponding to a specific NTP server entry.
NTP Server Address
Enter the IP address, the FQDN (Fully Qualified Domain Name) or the host name of the NTP
server.
NTP Server Port
Enter the port of the NTP server.
The following ports are possible:
123 (standard port)
1025 to 36564
Poll Interval
Specify the interval between two-time queries. The greater the interval, the less accurate the
time of the device.
Possible values are 64 to 2592000 seconds (30 days).
Key ID
Enter the ID of the authentication key.
Hash Algorithm
Specify the format for the authentication key.
Key
Enter the authentication key. The length depends on the hash algorithm.
The following minimum lengths are recommended for the hash algorithm:
MD5: ASCII 16 characters
SHA1: ASCII 20 characters
Key Confirmation
Enter the authentication key again to confirm it.
Configuring with Web Based Management
4.3 "Wizard" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 71