Configuring with Web Based Management 
  4.4 "System" menu 
SCALANCE SC-600 Web Based Management (WBM) 
Configuration Manual, 10/2021, C79000-G8976-C475-03 
139 
CLI script file 
You can download existing CLI configurations (RunningCLI) and upload your own CLI 
scripts (Script). 
Note 
The downloadable CLI script is not intended to be uploaded again unchanged.
 
CLI commands for saving and loading files cannot be 
executed with the CLI script file 
 
Exchange of configuration data with STEP 7 Basic/Professional using a file 
You use the two file types "RunningSINEMAConfig" and "SINEMAConfig" to exchange 
configuration data between a device (WBM) and STEP 7 Basic/Professional via a file. 
Requirements: 
•  Same article number 
•  Same firmware version 
•  Password 
You assign the password in the WBM under "System > Load&Save > Passwords". 
You can use the file types as follows: 
•  For offline diagnostics 
You can save the faulty configuration of a device as "RunningSINEMAConfig" via the 
WBM and import it in STEP 7 Basic/Professional. No connection to a real device is 
required for the diagnostics in STEP 7 Basic/Professional. You can export a corrected 
configuration and load it as "SINEMAConfig" again using the WBM. 
•  For configuration 
No connection to a real device is required to configure a device in STEP 7 
Basic/Professional. You can export the configuration and load it as "SINEMAConfig" 
to the real device using the WBM. 
X509 certificates 
The following file types can be loaded into the device:  
•  .crt, pem, zip: Maximum file name length 255 characters 
•  .p12: Maximum file name length 248 characters