Configuring with Web Based Management   
4.4 "System" menu 
  SCALANCE SC-600 Web Based Management (WBM) 
220  Configuration Manual, 10/2021, C79000-G8976-C475-03 
4.4.19  Port diagnostics 
4.4.19.1  Cable tester 
With this page, each individual Ethernet port can run independent fault diagnostics on 
the cable. This test is performed without needing to remove the cable, connect a cable 
tester and install a loopback module at the other end. Short-circuits and cable breaks 
can be localized to within a few meters. 
Note 
Please note that this test is permitted only when no data connection is established on 
the port to be tested.
 
If, however, there is a data connection to the port to be 
tested, this is briefly interrupted. 
-establishment of the connection can fail; in this case, the connection 
-established manually. 
To run a cable test at the combo port, the "Combo Port Media Type" "RJ45" must be set 
under 
"System > Ports > Configuration". 
 
Description 
The page contains the following boxes: 
•  Port 
Select the required port from the drop-down list. 
•  Run Test 
Activates error diagnostics. The result is shown in the table.