Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
171
4.4.9.4 SNMPv3 Access
Security settings and assigning permissions
SNMP version 3 allows permissions to be assigned, authentication, and encryption at
protocol level. The security level and read/write permissions are assigned according to
groups. The settings automatically apply to every member of a group.
Note
Different acces
s permissions for different security levels can be assigned to a group. If
no access permission is defined for a security level, no access to the device is possible
for members of the group using this security level.
Description
The page contains the following boxes:
• Group Name
Select the name of the group.
• Security Level
Select the security level (authentication, encryption) for which you want to define the
access permissions of the group:
– No Auth/no Priv
No authentication enabled/no encryption enabled.
– Auth/no Priv
Authentication enabled/no encryption enabled.
– Auth/Priv
Authentication enabled/encryption enabled.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals