Configuring with Web Based Management
4.6 "Layer 3" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
263
• Address Type
Shows the address type. The following values are possible:
– Primary
The first subnet of the interface.
– Secondary
All further subnets of the interface.
• TIA Interface
Select whether or not this interface should become the TIA Interface. The TIA
interface defines the VLAN on which the PROFINET functionalities are available. This
mainly affects the device search with or via DCP.
4.6.2 NAT
4.6.2.1 NAT General
On this WBM page, you enable Gratuitous ARP for alias IP addresses.
Description
On this page, you can enable the following option:
• Announce alias IP addresses
When the option is enabled, a Gratuitous ARP is sent for each alias IP address. This
announces the IP address in the network, and the other devices can update their ARP
cache. The Gratuitous ARP is only sent at the time of configuration, that is, during
device startup or when an NAT rule (NETMAP) is being configured.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals