Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
238 Configuration Manual, 10/2021, C79000-G8976-C475-03
Restoring factory settings
If you have restored the factory defaults, ring redundancy is disabled and the default
ports are used as the ring ports. This can lead to circulating frames and failure of the
data traffic if other settings were used in a previous configuration.
4.5.5 Spanning Tree
4.5.5.1 General
General settings of the Spanning Tree protocol
On this page, you can enable Spanning Tree and select the protocol compatibility. By
default, the "Spanning Tree Protocol" (STP) is enabled.
Description of the displayed boxes
The page contains the following boxes:
• Spanning Tree
Enable or disable Spanning Tree.
Note
No operation of Spanning Tree with enabled ring redundancy
If ring redundancy is enabled under "Layer 2", Spanning Tree cannot be used.
• Protocol Compatibility
Select the protocol compatibility. The following settings are available:
– STP
– RSTP

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals