Configuring with Web Based Management
4.3 "Information" menu
SCALANCE SC-600 Web Based Management (WBM)
88 Configuration Manual, 10/2021, C79000-G8976-C475-03
4.3.5.3 Firewall Log
The firewall log logs the events that occurred on the firewall. When you create firewall
rules, you can specify the event severity with which they are logged.
Description
• Severity Filters
You can filter the entries in the table according to severity. To display all the entries,
enable or disable all parameters.
Note
For each severity, a maximum of 400 entries in the table are possible. If the maximum
number of entries is reached for a severity, the oldest entries of this severity are
overwritten in the table. The table remains permanently in the
memory.
– Critical
Critical
When this parameter is enabled, all entries of the category "Critical" are displayed.
– Warning
warning
When this parameter is enabled, all entries of the category "Warning" are
displayed.
– Info
Informative
When this parameter is enabled, all entries of the category "Info" are displayed.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals