Configuring with Web Based Management 
  4.4 "System" menu 
SCALANCE SC-600 Web Based Management (WBM) 
Configuration Manual, 10/2021, C79000-G8976-C475-03 
197 
4.4.12  Button 
Functionality 
The SET button is used for: 
•  Resetting to factory settings. 
•  Defining the fault mask and the LED display. 
You will find a detailed description of the functions in the operating instructions for the 
device. 
On this page, the functionality of the button can be restricted. 
 
 
Description 
The following functionality is possible: 
•  Restore Factory Defaults 
When disabled, the SET button cannot be used to restore factory defaults. 
 
 
CAUTION 
Button function "Restore Factory Defaults" active during startup 
If you have disabled this function in your configuration, disabling is only valid during 
operation. When restarting, for example after power down, the function is active 
until the configuration is loaded so that the device can inadvertently be reset to the 
factory settings. This may cause unwanted disruption in network operation since the 
device then needs to be reconfigured. An inserted PLUG is also deleted and 
returned to the status as shipped. 
•  Set Fault Mask 
Enable or disable the function "Define fault mask via the LED display" with the 
SELECT/SET button.