Appendix A
A.3 Syslog messages
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
359
Tag Description Format Possible values or
String (with space) for the subject in the
certificate. Used as part of the certificate-based
authentication and must include Unicode
With UTF8 code: %S
detail}
String (with space) for the configuration
Name of the VPN connection
Firewall action executed (accepted package)
action
Firewall action executed (rejected package)
Length of the network packet (in bytes)
interface}
Symbolic name of a network interface
A.3 Syslog messages
This section describes the Syslog messages. The structure of the messages is based on
IEC 62443-3-3.
Some severities are grouped in the firmware:
Info + Notice = Info
Warning + Error = Warning
Critical + Emergency = Critical
Identification and authentication of human users
{protocol}: User {User name} has logged in from {ip address}.
WBM: User "Admin" has logged in from 192.168.0.1.
Valid login information that is specified during remote login.
IEC 62443-3-3 Reference: SR 1.1
{protocol}: User {User name} failed to log in from {ip address}.
WBM: User "Admin" has failed to log in from 192.168.0.1.
Incorrect user name or incorrect password (login information) specified
during remote login.