EasyManuals Logo
Home>Siemens>Switch>SIMATIC NET SCALANCE SC-600

Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Siemens SIMATIC NET SCALANCE SC-600
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #172 background imageLoading...
Page #172 background image
Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
172 Configuration Manual, 10/2021, C79000-G8976-C475-03
The table has the following columns:
• Select
Select the row you want to delete.
• Group Name
Shows the name of the SNMPv3 group.
• Security Level
Shows the security level to which this access permission applies.
• Read View Name
Enter an SNMPv3 view to be used for read SNMP access by members of the group
with the defined security level.
• Write View Name
Enter an SNMPv3 view to be used for write SNMP access by members of the group
with the defined security level.
Note
For write access to work, you also need to enable read access.
• Notification View Name
Enter an SNMPv3 view for which SNMP notification to members of the group with the
defined security level should be used.
Procedure
Creating a new group
1. Select the name of the group for which you are configuring SNMP access.
2. Select the required security level from the "Security Level" drop-down list.
3. Click the "Create" button to create a new entry.
4. In the "Read View Name" field, enter the SNMPv3 view for read access.
5. In the "Write View Name" field, enter the SNMPv3 view for write access.
6. In the "Notification View Name" field, enter the SNMPv3 view for notifications.
7. Click the "Set Values" button.
Modifying a group
Once a group name and the security level have been specified, they can no longer be
modified after the group is created. If you want to change the group name or the security
level, you will need to delete the group and create it and configure it with the new name.
Deleting a group
1. Enable "Select" in the row to be deleted.
Repeat this for all groups you want to delete.
2. Click the "Delete" button. The entries are deleted.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals