Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
161
Description
The page contains the following boxes:
• Pool ID
Select the required address band.
• Option Value
Enter the number of the required DHCP option.
Note
DHCP options supported
The DHCP options 1, 3, 6, 12, 15, 66, 67 are supported.
The DHCP options are created automatically when the IPv4 address band is created.
With the exception of option 1, the options can be deleted.
The table has the following columns:
• Select
Select the check box in the row to be deleted
• Pool ID
Shows the number of the address band.
• Option Value
Shows the number of the DHCP option.
• Description
Text describing the option value.