Programming via XML interface
10.3 XML commands
SIMATIC RF600
148 Configuration Manual, 11/2018, C79000-G8976-C386-07
10.3.1.4
setIPConfig
This command is available as of API V2.2.
The IP address of the reader is changed with this command. If the transferred parameters do
not contain any inconsistencies, the reader will terminate the connection. This happens as
well if the parameters are identical to the previous settings. A response frame is sent in reply
to this command only if there is an error.
Command
<frame>
<cmd>
<id> value_id </id>
<setIPConfig>
<iPAddress> value_iPAddress </iPAddress> // opt
<subNetMask> value_subNetMask </subNetMask> // opt
<gateway> value_gateway </gateway> // opt
<dHCPEnable> value_dHCPEnable </dHCPEnable> // opt
</setIPConfig>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setIPConfig/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_iPAddress IP address 1.0.0.1…
255.255.255.254
IP address of the reader
Parameter is ignored, if DHCP is acti-
vated:
value_dHCPEnable = True