Programming via XML interface
10.4 XML EventReports
SIMATIC RF600
220 Configuration Manual, 11/2018, C79000-G8976-C386-07
10.4.1.2
rssiEventReport
An RSSI event report signals a change in the RSSI values when reading the transponders.
RSSI events are generated separately for each antenna.
The data type and amount are specified by the settings in the basic configuration in the
WBM.
Report
<frame>
<report>
<id> value_id </id>
<rssier>
<tag>
<sourceName> value_sourceName </sourceName>
<tag>
<tagID> value_tagID </tagID>
<tagPC> value_tagPC </tagPC> // opt
<utcTime> value_utcTime </utcTime> // opt
<antennaName> value_antennaName </antennaName> // opt
<rSSI> value_rSSI </rSSI> // opt
<channel> value_channel </channel> // opt
<power> value_power </power> // opt
<polarization> value_polarization </polarization> // opt
</tag>
<tag> // opt
</tag> // opt
</rssier>
</report>
</frame>
// opt → Optional: Depending on the parameter assignment or the amount of data, the line
can be omitted.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<rssier/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".