Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
183
value_rSSI Decimal value
0...9
0...255 Optional
Largest measured RSSI value
value_channel Decimal value
0...9
1...50 Optional
Channel number on which the tran-
value_power Decimal value
0...9
0, 5.00...33.00 Optional
Used radiated power of the antenna in
[dB]
value_polarization Fixed values Default
Circular
Linear_vertical
Linear_horizontal
All
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
value_inventoried Decimal value
0...9
0...65535 Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-
value_
filterDataAvailable
Fixed values True
False
Optional
Indicates whether or not a filter criteri-
on was received.
• True:
All the data was read or there was
no filter set.
• False:
This command writes a new EPC-ID to the transponder. To ensure clear identification when
writing the ID, there must be only one transponder in the antenna field. If there is more than
one transponder in the antenna field, a negative reply is returned.
<sourceName> value_sourceName </sourceName>
<tagID> value_tagID </tagID> // opt
<newID> value_newID </newID>
<idLength> value_idLength </idLength> // opt
<password> value_password </password> // opt