Appendix
A.2 Command and acknowledgement frames
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
277
A.2.2
READER-STATUS or DEV-STATUS
Reads out the status of a reader/communications module.
Table A- 3 Command
Byte
0, 1 2, 3 4 5 6, 7 8 9 10 11 12 ... 19 20 ... 27
Mean-
ing
DBL SN CC CI TDB DBN_H DBN_L DBL -- -- --
Value
35 -- 't' 'A' 1 -- 1 35 0 0 0
Byte
28 ... 31
32, 33
34
35
36, 37
38
39
40, 41
42, 43
44, 45
Mean-
ing
-- -- -- -- -- ATT -- -- -- --
Value
0
0
0
0
0
89
0
0
0
0
Table A- 4 Reply
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
11 ... 239
Mean-
ing
DBL SN CC STATUS TDB DBN_H DBN_L DBL SLG-
STATUS
Value
--
--
't'
xx
1
--
1
--
--