Appendix
A.2 Command and acknowledgement frames
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
287
A.2.12
WRITE-CONFIG
Sends new parameters to the reader/communications module.
Table A- 32 Command
Byte
0, 1 2, 3 4 5 6, 7 8 9 10 11 12 ... 19 20 ... 27
Mean-
ing
DBL SN CC CI TDB DBN_H DBN_L DBL CONFI
G
-- --
Value
-- -- 'x' 'A' -- -- -- -- xx 0 0
Byte
28 ... 31 32, 33 34 35 36, 37 38 39 40, 41 42, 43 44, 45 46 ...
239
Mean-
ing
-- LENGT
H
-- -- -- -- -- -- -- -- CONFI
G_DAT
A
Value
0
xx
0
0
0
0
0
0
0
0
xx
Table A- 33 Reply
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
11 ... 13
Mean-
ing
DBL SN CC STATUS TDB DBN_H DBN_L DBL MAX_
PACKAG
E
SIZE
Value
2
--
'x'
xx
1
--
1
2
xx