Programming via XML interface
10.3 XML commands
SIMATIC RF600
162 Configuration Manual, 11/2018, C79000-G8976-C386-07
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_utcTime Time -- UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
Note: The reader only accepts time
information from 01.01.2000 ...
18.01.2038.
10.3.2.10
getTime
This command requests the current time stamp of the internal reader clock.
Command
<frame>
<cmd>
<id> value_id </id>
<getTime/>
</cmd>
</frame>
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getTime>
<returnValue>
<utcTime> value_utcTime </utcTime>
</returnValue>
</getTime>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".