Programming via XML interface
10.3 XML commands
SIMATIC RF600
200 Configuration Manual, 11/2018, C79000-G8976-C386-07
10.3.3.10
writeTagField
This command writes data to the selected transponder. The address of the data area is
specified by the name of a tag field. The tag field and the name of the field are specified
using the WBM.
If no EPC-ID is made available or detected, the command is executed with all the
transponders recognized from the read point.
Note
If no EPC
-ID is specified, the results are influenced by all the set filter mechanisms (refer to
the section "
The "Settings - Filters" menu item (Page 66)"). Then in the reply frame, only the
tags that were not filtered out appear. If an EPC
-ID is specified, the data filter has no effect.
The reply frame contains the IDs of all identified transponders. A flag for each transponder
indicates whether or not the command was successful for this transponder.
If no transponder was identified, a negative reply is returned.
Command
<frame>
<cmd>
<id> value_id </id>
<writeTagField>
<sourceName> value_sourceName </sourceName>
<tagID> value_tagID </tagID> // opt
<password> value_password </password> // opt
<tagField>
<fieldName> value_fieldName </fieldName>
<data> value_data </data>
</tagField>
<tagField> // opt
</tagField> // opt
</writeTagField>
</cmd>
</frame>
// opt → Optional: Line can be omitted.