Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
207
value_airRetry Decimal value
0...9
0...65535 Optional
Number of times the reader repeated
air interface commands attempting to
obtain correct data.
"0" corresponds to no attempt.
The maximum number of attempts is
specified in the reader firmware and
value_
filterDataAvailable
Fixed values True
False
Optional
Indicates whether or not a filter criteri-
on was received.
• True:
No problem All the data was read
or there was no filter set.
• False:
This command locks the memory area of the selected transponder. If no EPC-ID is made
available or detected, the command is executed with all the transponders recognized from
the read point.
-ID is specified, the results are influenced by all the set filter mechanisms (refer to
The "Settings - Filters" menu item (Page 66)"). Then in the reply frame, only the
transponders that were not filtered out appear. If an EPC
-ID is specified, the data filter has
The reply frame contains the IDs of all identified transponders. A flag for each transponder
indicates whether or not the command was successful for this transponder.
If no transponder was identified, a negative reply is returned.
Below, there is a brief description of the "epcGen2LockAction" and "epcGen2LockMask"
parameters. The first row of the table ('Bit') indicates the bit positions of the action and the
masking values. The masking and action values are specified first with the MSB.
Further information on the parameters can be found in the "EPCglobal Specification
(http://www.gs1.org
)."
Table 10- 2 Structure of the parameters "epcGen2LockAction" and "epcGen2LockMask"
s/w s/w s/w s/w s/w s/w s/w s/w s/w s/w