Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
161
RssiDelta 0...255 Source See descrip-
tion
Difference for RSSI values
Maximum difference compared
with the RSSI value of the tran-
sponder with the highest RSSI
value that the transponders can
have and still be processed.
This is a value without a unit
and without direct reference to
the power strength.
"objName" must have the name
of the corresponding read point.
Modula-
tionScheme
32, 33, 34, 35,
37, 65
General General Modulation scheme of the read
point
This also specifies which tran-
sponder types are identified
This command sets the internal reader clock.
<utcTime> value_utcTime </utcTime>
<resultCode> 0 </resultCode>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".