69
7. Mask: Enter the value "0F" in the input box.
This specifies the positions in the EPC-ID relevant for filtering out.
8. Inclusive/exclusive filters: Select the "Inclusive filter" filter type.
Figure 7-11 Example of a filter
9. Unreadable filter data: Select how the reader handles transponders whose filter data
cannot be read out.
10.Enable the filter in the "Settings - Read points" menu item and transfer the configuration
to the reader.
7.3.6
The "Settings - Digital outputs" menu item
In the "Settings - Digital outputs" menu item, you can set the properties of the digital outputs
and assign functions to the individual outputs. For each output there is an identical tab
divided into 2 areas:
Basic settings
Events