Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
163
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_utcTime Time -- UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
10.3.2.11
setIO
This command sets the digital outputs of the reader.
The general settings for the response of the outputs such as "Inactivity" or "Reset time"
specified using the WBM in a base configuration (see also section "The "Settings - Digital
outputs" menu item (Page 69)").
Command
<frame>
<cmd>
<id> value_id </id>
<setIO>
<outValue> value_outValue </outValue>
</setIO>
</cmd>
</frame>
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setIO/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".