Service and maintenance
13.2 Error messages
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
253
Command repetition is not supported.
-- 0x7A 0xE7FE0A Error during the transfer of the PDU (Protocol Data Unit).
"--" means that the error is not displayed by the LEDs.
The following table lists the OPC UA-specific error codes.
Table 13- 3 OPC UA error messages of the RF600 readers
1 0xCA good MISC_ERROR_
General error
1 0xCD good MISC_ERROR_
TOTAL
• Firmware error
Possible cause: The firmware update was not run
completely.
• Internal communications error of the communications
module/reader
– Connector contact problem on the communica-
tions module/reader
– Hardware of the communications module / reader
has a defect; → Send in communications module /
reader for repair
– Start "INIT" after correcting the error
• Internal monitoring error of the communications mod-
ule/reader
– Program execution error on the communications
module / reader
– Turn the power supply of the communications
module/reader off and on again
– Start "INIT" after correcting the error
1 0xE6 good MISC_ERROR_
The inventory command failed.
1 0xEA good MISC_ERROR_
Enabling write protection on the transponder failed.
1 0xEB good MISC_ERROR_
The "Kill" command failed.
3 0x1A good PERMISSON_
The transponder is read/write-protected.
4 0x92 good PASSWORD_
The transponder password is incorrect. Access is denied.