Service and maintenance
13.2 Error messages
SIMATIC RF600
254 Configuration Manual, 11/2018, C79000-G8976-C386-07
5 0x63 Bad
Invalid
Argument /
good
REGION_NOT_
FOUND_ERROR
All commands:
A parameter of an OPC UA command has an invalid
value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the cur-
7 0x13 good OUT_OF_RANGE_
ERROR
Address error
The address area of the transponder has been exceeded.
Possible causes:
• Start address of the command start has been incor-
rectly set.
• Wrong transponder type
• The area to be written to is write-protected.
7 0xA2 good OUT_OF_
The requested data is not available.
8 0xA1 good NO_
IDENTIFIER
There is no transponder with the required EPC ID in the
transmission window or there is no transponder at all in
9 0x22 good MULTIPLE_
IDENTIFIERS
More transponders are located in the transmission win-
dow than can be processed at the same time by the
9 0xA7 good MULTIPLE_
There is more than one transponder in the transmission
10 0xE7 good READ_
Read access to the transponder failed.
14 0xE8 good WRITE_
Write access to the transponder failed.
14 0xE9 good WRITE_
ERROR
Writing the EPC-ID on the transponder failed.
15 0x61 good NOT_SUPPORTED_
BY_DEVICE
Unknown command
An uninterpretable XML command was sent to the reader
or the Ident profile sends an uninterpretable command to
the reader.
Possible causes:
• The "AdvancedCmd" block was supplied with an in-
correct "CMD".
• The "CMD" input of the "AdvancedCmd" block was
overwritten.
17 -- good DEVICE_NOT_
The specified read point is not active because no antenna
18 0xC1 good INVALID_
The specified tag field of the transponder is unknown.
19 0x91 good RF_COMMUNICATION_
The transponder is not responding.