EasyManua.ls Logo

Siemens SIMATIC RF615R - Negative XML Replies

Siemens SIMATIC RF615R
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
213
10.3.4
Negative XML replies
If problems occur during the execution of the command, the reader reports this to the user
application. These error messages always include an event code ≠ 0 and information about
the problem.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> value_resultCode </resultCode>
<error>
<name> value_name </name>
<cause> value_cause </cause>
</error>
</reply>
</frame>
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_resultCode Decimal value
0...9
0...65535 Identification number of the error
You will find a list of possible return
codes in the following table.
value_name Text -- Textual description of the error
You will find descriptions of the prob-
lems in the following table.
value_cause Text -- Brief description of the cause of the
negative reply.
List of possible result codes
Result code
Name
Description
hex
dec
0x00 0 NO_ERROR Positive reply, command processed suc-
cessfully.
0x13 19 ERROR_MEMORY_OVERRUN Access outside the addressed memory
area.
0x1A 26 ERROR_TAG_LOCKED The transponder to which data is meant to
be written or which should be deactivated is
locked.
0x91
145
ERROR_NO_ASWER_FROM_TAG
The transponder is not responding.