Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
169
value_id Decimal value
0...4294967295 Unique command identifier
value_readerType Fixed values SIMATIC_RF680R
SIMATIC_RF685R
SIMATIC_RF650R
Reader type
value_mLFB Alphanumeric text -- SIEMENS article number of the reader
Example: 6GT2811-6AA10-0AA0
value_hWVersion Alphanumeric text -- Hardware version of the reader
Example: V1.0.0.0_1.1.0.34
value_fWVersion Alphanumeric text -- Firmware version of the reader
Example: V1.0.0.0_1.1.0.34
value_version Alphanumeric text -- Reader-specific version of components
Note that the number of sub-versions
can change.
In future versions, there may be more
With this command, the names of all configured read points of the reader are queried.
<resultCode> 0 </resultCode>
<sourceName> value_sourceName </sourceName>
<sourceName> value_sourceName </sourceName> // opt