Appendix
A.2 Command and acknowledgement frames
SIMATIC RF600
284 Configuration Manual, 11/2018, C79000-G8976-C386-07
The black list is processed. The current transponder can be added, all identified
transponders added, individual transponders deleted or all transponders deleted.
Table A- 23 Command
0, 1 2, 3 4 5 6, 7 8 9 10 11
DBL SN CC CI TDB DBN_H DBN_L DBL MODE
78 -- 'z' 'U' 1 0 1 -- xx
12 13 14, 15 16, 17 18 ... 21 22, 23 24, 25 26 27 ... 88
SOURCE -- -- -- -- -- -- IDLENGT
EPC-ID
Table A- 24 Reply
Table A- 25 Description of the bytes
11 Mode:
• 0x00 = add TagID
• 0x01 = add all "Observed" transponders
• 0x02 = delete TagID
• 0x03 = delete all
26 Length of the EPC ID:
• 0x00 = not addressed
Buffer for up to 62 bytes EPC-ID