Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
173
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<editBlacklist/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_
sourceName
Text -- Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 52
)").
In the standard configuration, there is
only one read point with the name
"Readpoint_1".
value_ blackList-
Cmd
Fixed values Add
Add_obs
Del
Del_all
How "setBlacklist" works:
Add: all the following EPC-IDs will
be saved
Add_obs: all EPC-IDs with the
"observed" status are stored in the
black list.
Del: all the following EPC-IDs will
be removed from the black list
Del_all: All entries in the black list
will be removed.
value_tagID Hexadecimal
value
0...9, A...F
-- EPC-ID in "RAW Hex Data Format"
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".