Programming via XML interface
10.3 XML commands
SIMATIC RF600
176 Configuration Manual, 11/2018, C79000-G8976-C386-07
<resultCode> 0 </resultCode>
For negative replies ("resultCode" ≠ 0), refer to the description in the section "Negative XML
replies (Page 213)".
value_id Decimal value
0...4294967295 Unique command identifier
value_
sourceName
Text -- Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 52
)").
In the standard configuration, there is
only one read point with the name
value_
triggerMode
Fixed values Single
Start
Stop
Optional
Trigger type ( default = single)
The duration and number can be set
up via the Web-based interface.
• Single
Single triggering of the read point.
• Start
The read point is continuously trig-
gered until a stop command is sent.
• Stop
Stops triggering of the read point.
Note that this command is only ef-
fective for previously executed trig-
ger commands. The command has
no effect on any configured contin-