Programming via XML interface
10.3 XML commands
SIMATIC RF600
188 Configuration Manual, 11/2018, C79000-G8976-C386-07
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<readTagMemory>
<returnValue>
<tag>
<tagID> value_tagID </tagID>
<tagPC> value_tagPC </tagPC> // opt
<success> value_success </success>
<utcTime> value_utcTime </utcTime> // opt
<antennaName> value_antennaName </antennaName> // opt
<rSSI> value_rSSI </rSSI> // opt
<channel> value_channel </channel> // opt
<power> value_power </power> // opt
<polarization> value_polarization </polarization> // opt
<commandRetry> value_commandRetry </commandRetry> // opt
<airRetry> value_airRetry </airRetry> // opt
<filterDataAvailable> value_filterDataAvailable
</filterDataAvailable> // opt
<tagField> // opt
<bank> value_bank </bank>
<startAddress> value_startAddress </startAddress>
<dataLength> value_dataLength </dataLength>
<data> value_data </data>
</tagField> // opt
<tagField> // opt
</tagField> // opt
</tag>
<tag> // opt
</tag> // opt
</returnValue>
</readTagMemory>
</reply>
</frame>
// opt → Optional: Line can be omitted. In the reply, the parameter is transferred depending
on the configuration settings (engineering/communication).
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative