Programming via XML interface
10.3 XML commands
SIMATIC RF600
198 Configuration Manual, 11/2018, C79000-G8976-C386-07
value_tagPC Hexadecimal
value
0...9, A...F
-- Optional
Tag PC (Protocol Control)
16-bit value represented by four hexa-
decimal characters.
Example:
The value "1234" corresponds to the
binary value "0001.0010.0011.0100".
value_fieldName Hexadecimal
value
-- Name of tag field
Is specified using the WBM.
value_password Hexadecimal
value
0...9, A...F
00000000...
FFFFFFFF
Optional
Access password for the transponder
This parameter does not need to be
defined if there is no password protec-
tion activated for the transponder.
value_success Fixed values True
False
Flag to indicate whether or not the
command was successful for this tran-
sponder.
• True: Command successful
• False: Command unsuccessful
value_utcTime Time -- Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
value_
antennaName
Fixed values Antenna01
Antenna02
Antenna03
Optional
Name of the antenna
value_rSSI Decimal value
0...9
0...255 Optional
value_channel Decimal value
0...9
1...50 Optional
Channel number on which the tran-
value_power Decimal value
0...9
0, 5.00...33.00 Optional
Used radiated power of the antenna in
[dB]
value_polarization Fixed values Default
Circular
Linear_vertical
Linear_horizontal
All
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the