Programming via XML interface
10.3 XML commands
SIMATIC RF600
202 Configuration Manual, 11/2018, C79000-G8976-C386-07
value_tagID Hexadecimal
value
0...9, A...F
-- Optional
EPC-ID in "RAW Hex Data Format".
This function applies to all transpond-
ers with this ID.
If this parameter is empty or not even
transferred, the function applies to all
transponders. Nevertheless only one
transponder is then permitted in the
antenna field.
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
value_tagPC Hexadecimal
value
0...9, A...F
-- Optional
Tag PC (Protocol Control)
16-bit value represented by four hexa-
decimal characters.
Example:
The value "1234" corresponds to the
binary value "0001.0010.0011.0100".
value_fieldName Hexadecimal
value
0...9, A...F
-- Name of tag field
Is specified using the WBM.
value_password Hexadecimal
value
0...9, A...F
00000000...
FFFFFFFF
Optional
Access password for the transponder
This parameter does not need to be
defined if there is no password protec-
tion activated for the transponder.
value_data Hexadecimal
value
0...9, A...F
-- Data that should be written. Each byte
is represented by two hexadecimal
characters.
Example:
The byte sequence "0x12, 0x34, 0xA3"
is represented as the character string
"1234A3" in the "value_data" parame-
ter.
"value_dataLength" is 3 in this exam-
value_success Fixed values True
False
Flag to indicate whether or not the
command was successful for this tran-
sponder.
• True: Command successful
• False: Command unsuccessful
value_utcTime Time -- Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.