Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
205
<power> value_power </power> // opt
<polarization> value_polarization </polarization> // opt
<commandRetry> value_commandRetry </commandRetry> // opt
<airRetry> value_airRetry </airRetry> // opt
<filterDataAvailable> value_filterDataAvailable
</filterDataAvailable> // opt
</tag>
<tag> // opt
</tag> // opt
</returnValue>
</killTag>
</reply>
</frame>
// opt → Optional: Line can be omitted. In the reply, the parameter is transferred depending
on the configuration settings (engineering/communication).
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_
sourceName
Text -- Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 52
)").
In the standard configuration, there is
only one read point with the name
"Readpoint_1".
value_tagID Hexadecimal
value
0...9, A...F
-- Optional
EPC-ID in "RAW Hex Data Format".
This function applies to all transpond-
ers with this ID.
If this parameter is empty or not even
transferred, the function applies to all
transponders. Nevertheless only one
transponder is then permitted in the
antenna field.
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".