Programming via XML interface
10.4 XML EventReports
SIMATIC RF600
218 Configuration Manual, 11/2018, C79000-G8976-C386-07
value_event Fixed values New
Glimpsed
Observed
Lost
The transponder events are also gen-
erated by a smoothing algorithm in the
read point. The algorithms are speci-
fied in the WBM.
A report can also contain more than
one event for the same transponder.
Each individual event has its own tran-
sponder structure.
If a report contains two events for the
same transponder, two transponder
structures exist with the same "val-
ue_tagID" but different values for "val-
value_utcTime Time -- UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
value_
antennaName
Fixed values Antenna01
Antenna02
Antenna03
Antenna04
Name of the antenna
value_rSSI Decimal value
0...255 RSSI value
rSSIMin Decimal value
0...9
0...255 The lowest RSSI value with which the
transponder was detected. This is a
value without a unit and without direct
reference to the power strength.
rSSIMax Decimal value
0...9
0...255 The highest RSSI value with which the
transponder was detected. This is a
value without a unit and without direct
reference to the power strength.
value_channel Decimal value
0...9
1...50 Optional
Channel number on which the tran-
value_power Decimal value
0...9
0, 5.00...33.00 Optional
Used radiated power of the antenna in
[dB]
value_polarization Fixed values Circular
Vertical
Horizontal
Polarization of the antenna.
With external antennas always un-
known.
value_inventoried Decimal value
0...9
0...65535 Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-