EasyManua.ls Logo

Siemens SIMATIC RF615R - Page 222

Siemens SIMATIC RF615R
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming via XML interface
10.4 XML EventReports
SIMATIC RF600
222 Configuration Manual, 11/2018, C79000-G8976-C386-07
Report
<frame>
<report>
<id> value_id </id>
<ioer>
<io>
<ioName> value_ioName </ioName>
<ioEvent> value_ioEvent </ioEvent>
<utcTime> value_utcTime </utcTime>
</io>
<io> // opt
</io> // opt
</ioer>
</report>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<ioer/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_ioName Fixed values Inport00
Inport01
Inport02
Inport03
Outport00
Outport01
Outport02
Outport03
Name of IO port

Table of Contents