Programming via XML interface
10.4 XML EventReports
SIMATIC RF600
222 Configuration Manual, 11/2018, C79000-G8976-C386-07
<ioName> value_ioName </ioName>
<ioEvent> value_ioEvent </ioEvent>
<utcTime> value_utcTime </utcTime>
// opt → Optional: Line can be omitted.
<resultCode> 0 </resultCode>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".
value_id Decimal value
0...4294967295 Unique command identifier
value_ioName Fixed values Inport00
Inport01
Inport02
Inport03
Outport00
Outport01
Outport02
Name of IO port