Programming via XML interface
10.4 XML EventReports
SIMATIC RF600
224 Configuration Manual, 11/2018, C79000-G8976-C386-07
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_
errorNumber
Decimal value 0 -
9
0...65535 Error number
You will find a list of error numbers in
the following table.
value_utcTime Text -- UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
value_errorText
Text
--
Message text of the alarm
Value_eventType Text Coming
Going
Status display
Some alarms have a simple status
indication. This indicates whether the
error occurred and is still present or
whether it has been eliminated.
value_paramXY Text -- Additional parameter
The name of the parameter depends
on the error. Depending on the error
number, an alarm contains a different
number of parameters.
List of possible alarm messages
Error number
Description
hex
dec
0x1511 5393 ERROR_NO_ANSWER_FROM_TAG
The transponder is not responding.
0x1512 5394 ERROR_WRONG_PASSWORD
The password you entered is incorrect. Access to the transponder was denied.
0x1513 5395 ERROR_VERIFY_TAG_FAILED
Verification of the transponder failed.
0x1514 5396 ERROR_TAG_UNSPECIFIED
General transponder error.
0x1515 5397 ERROR_TAG_INSUFFICIENT_POWER
There is not enough transponder power.
0x1521 5409 ERROR_NO_TAG
There is no transponder in the antenna field.
0x1522 5410 ERROR_NO_DATA
The requested data is not available.
0x1523 5411 ERROR_INVALID_CRC
Bad checksum
0x1525 5413 ERROR_NO_FREQUENCY
No radio channel activated.